Home

If wire rope guardrails are used, what must also be done OSHA

Clips used for wire rope guardrails; required fall

Clips used for wire rope guardrails; required fall protection in hoist area. Alert: Due to routine maintenance on the OSHA website, some pages may be temporarily unavailable. To report an emergency, file a complaint with OSHA or ask a safety and health question, call 1-800-321-6742 (OSHA) If wire rope guardrails are used, what must also be done? B They must be flagged with highly visible materials at least every six feet Keys to preventing a fall from a ladder include choosing the right ladder for the job and tying the top and bottom of the ladder to fixed points. What else can you do to keep safe when using a ladder protection must be used by your employer. If your employer uses guardrails: Toprails must be at least ¼ inch thick to prevent cuts and lacerations; and they must be between 39 and 45 inches from the working surface; If wire rope is used, it must be flagged at least every six feet with highly visible materials; Midrails, screens or mesh must be.

osha Flashcards Quizle

If wire rope guardrails are used, what must also be done? They must be flagged with highly visible materials at least every six feet What is being described in the following definition: An opening in the floor, platform, or pavement that measures 12 inches or more, and through which persons may fall If workers are utilizing stilts in an area protected by guardrails, the 42 requirement must be extended to match the height of the stilts Wire rope may be used for guardrails, provided that it is at least 1/4 inch in diameter to prevent cuts and lacerations and it's marked or flagged at not more than 6-foot intervals with high-visibility material

Walking Working Surfaces Assessment Flashcards Quizle

Removable sections of guardrails for incoming materials must be replaced and structurally sound after materials are loaded. (3) Guardrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds applied within 2 inches of top edge, in any outward or downward direction, at any point along the top edge The top rail or midrails must not be made from steel or plastic banding. The top rail and midrails must be at least ¼ inch in diameter or thickness to prevent cuts. If a wire rope is used for the top rail, it must be flagged no more than every six feet with high-visibility material Section 4.58(4.1) of the Regulation specifies that guardrails made of fibre or wire rope temporarily installed during the construction, demolition, or renovation of a work area must meet the requirements of WorkSafeBC Standard - Guardrails using rope or other non-rigid material (Schedule 4-A) (1.2 m) or more above adjacent floor or ground level shall be guarded by a guardrail system (or equivalent) along all open sides (except where there is an entrance to a ramp, stairway or fixed ladder). The guardrail system shall be provided with a toeboard when necessary. > See Section 21.F.01 Protect wire rope from sharp or abrasive edges of building. Do not use wire rope that has been exposed to fire, excessive wear, corrosive atmosphere, chemicals, passage of electric current, or temperatures above 200 F. 8. Inspect the wire rope before rigging. Handle, inspect, and maintain wire rope carefully during and after each job

(a)(7)(v) In standing ropes, more than two broken wires in one lay in sections beyond end connections or more than one broken wire at an end connection. (a)(7)(vi) Wire rope safety factors shall be in accordance with American National Standards Institute B 30.5-1968 or SAE J959-1966 Guardrail Systems. Frequently inspect manila, plastic, or synthetic rope used for top rails or midrails to ensure that the rope meets the minimum strength and rail height requirements. [See 1926.502(b)] Safety-Net Systems. Inspect safety nets for damage or deterioration weekly and after any event that could damage them Construction Focus Four: Fall Hazards. Protective barriers must be strong enough to support a falling employee. Wood, chain and wire rope may be used for top rails and midrails. Top rails - 36-48 inches tall when using the crossbracing as the top rail. When crossbracing is used as a midrail, it must be between 20 and 30 inches above the work platform. Guardrails are not required Guardrails must be 2 X 4 inches, or the equivalent, approximately 42 inches high, with a midrail, when required. Supports must be at intervals not to exceed 8 feet. Toe boards and the guardrails, extending along the entire opening, shall consisting of No. 18 gauge U.S. standard wire ½ inch mesh, or the equivalent

A travel restraint (tether) line defined in 1910.140(b) means a rope or wire rope used to transfer forces from a body support to an anchorage or anchorage connector in a travel restraint system. Travel restraint lines must be capable of sustaining a tensile load of at least 5,000 pounds (22.2 kN) is not defined although 3 inches of deflection for wire rope after force is applied is a guideline. Strength criteria also applies to all structural members of system, including post anchorages. 4. There is no OSHA national office guidance at this time for size of wire rope guardrails. Three-eighth The other members used must also Material Requirements If a guardrail is used . The OSHA standard provides several requirements for the finish If a wire rope is used for the top rail, it must be flagged no more than every six feet with high-visibility material

What is the Appropriate Height for Guardrail and Fall

  1. That's it. The standard authorizes a guardrail but nothing else. However, in 1976, OSHA published a proposed revision to Part 1910, Subparts D and I, allowing the use of alternate fall protection, which would include the use of personal fall protection, with the caveat where the use of guardrails is not feasible
  2. OSHA emphasizes that safety-monitoring systems are a last resort and may only be used when other systems are infeasible or present a greater hazard. Monitoring systems must be developed in accordance with OSHA regulation 1926.502 and must be approved by EH&S or their designees before employees are exposed to fall hazards
  3. According to OSHA a guardrail system can be used as a barrier installed to prevent workers from falling off a work surface edge to a lower level. Guardrail systems can be used on surfaces included rooftops, platforms, mezzanines, balconies, scaffolds, decked floors, catwalks, observation platforms, mobile work surfaces and ladder points of access
  4. Falls from ladders may result from problems with the selection, maintenance or use of a ladder. Common causes of straight ladder falls may be slippage due to failure to properly secure the ladder at the top and/or bottom, erecting the ladder at too steep or too shallow angle, climbing the ladder while using one or both hands to carry tools or supplies, and overreaching while working on the ladder
  5. February 1, 2014 - When I conduct OSHA 10 and 30-hour training classes, most students seem to know that Federal OSHA requires some form of fall protection for employees working at heights greater than four (4) feet in General Industry (), and at heights over six (6) feet in Construction ().However, many of them are unaware that there are numerous other OSHA standards requiring fall protection.
  6. Where scaffolds are to be suspended using wire or fiber rope, the same must be capable of supporting at least six times the intended load. Only treated fiber rope should be used for or near work involving the use of corrosive substances or chemicals, and only wire rope-supported scaffolds used for cleaning buildings over 50' in height with.
  7. Any repair necessary to the scaffold must be done immediately. Guardrails, midrails and toeboards are mandatory. Platforms must be tightly planked and built with appropriate material. A capable person should inspect the scaffold once finished, and at designated intervals. All rope must be protected from sources of heat

Understanding OSHA's Fall Protection Standard EHS Toda

  1. Fall protection can be provided by guardrails, safety nets, and/or a personal fall protection system. The upper railing of the specially built platform has a stainless steel wire rope secured.
  2. Inspect all screw, bolts, nuts and any other fastening devices to ensure they are not loose or missing. Also make sure they haven't been altered in any way. Look for rust, corrosion or any other deterioration of the metal components. Inspect your rope for broken wires (wire rope), broken threads (synthetic rope), or any other obvious damage
  3. When a wire rope bridle is used, each leg must be connected to a master line (D-ring) or shackle with the load evenly distributed. Don't use the bridle for any other purpose. All rigging hard w a r e must be able to s u p p o r t five times the maximum in-tended load. If nonrotational rope is used, increase the safety factor to 10
  4. 145. In hoisting areas where guardrails are used and guardrails are removed to facilitate landing of material and the employee must lean out over the edge or through the access opening, is that employee protected by a fall arrest system? 1926.501(b)(3) Yes. No. N/A. Comments. 146

OSHA #2.pdf - Among the rights related to OSHA ..

  1. The use of repaired wire rope is prohibited. Drum hoists must contain no less than 4 wraps of the rope at the lowest point. All support devices must rest on surfaces capable of supporting at least 4 times the load imposed on them by the scaffold when operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the scaffold at the stall capacity of the hoist.
  2. imum breaking strength of 5,000 lbs. (22.2 kN). The kernmantle rope lanyard is adjustable and was manufactured for workers that must transition around obstacles. Wire rope lanyards provide heat resistance and are also highly abrasion resistant
  3. The maximum arresting force on an employee must be limited to 1,800 pounds when using a harness. 3. The employee cannot free fall more than 6 feet or contact any lower level. 4. The employee must.
  4. us 3 inches (8 cm) above the walking/working level
  5. employee walking along an unprotected edge, a wire rope guardrail that was only 32 inches above the wal ki ng /worki ng surface, and caut ion t ape used as fal l prot ect ion al ong the edg e of an open-si ded floor. He also saw a 10.5-inch-diameter uncovered floor hole in addition to floor holes with cover
  6. g traffic, crashing against solid objects or falling into a ravine
  7. c. The wire rope is free of defects and is the size and type specified for the hoist; d. Guardrails and toe boards are properly installed; e. The main suspension wire rope is vertical. 14. Use approved personnel harnesses, lanyards, rope grabs, and independent lifelines at all times

Crane & Derrick Compliance. OSHA's new Crane and Derrick standard has a little something for everyone, including some unexpected compliance issues for the electric utility industry. Known as Subpart CC, the standard was years in development, pushed heavily to completion in the last years by serious and highly publicized crane accidents Guardrail Systems-Non-mandatory Guidelines for Complying with 1926.502(b) describes how to design and build guardrails to comply with OSHA regulations. Wood components, if used for guardrails, must be at least 1,500-pound-per-foot construction grade lumber, the posts must be 2-by-4-inch lumber spaced no more than eight feet apart, and top.

The Ladder Effect at Guardrailings & Stair Guard

use. 3 Guardrail Systems. defined as a barrier erected to prevent workers from falling to lower levels. A guardrail system must be used ; on unprotected sides or edges of a ramp or runway. on unprotected sides or edges of holes. to restrict access to hoist areas when not used for hoisting. 4 Guardrail Systems. No openings can be more than 19 apart Diversified Fall Protection has served clients spanning a wide range of industries since 1994. Our holistic, managed approach to safety ensures full compliance with all OSHA fall protection regulations and safeguards the well-being of your employees. Download the e-book c. The wire rope is free of defects and is the size and type specifi ed for the hoist; d. Guardrails and toe boards are properly installed; e. The main suspension wire rope is vertical. 13. Use approved personnel harnesses, lanyards, rope grabs, and independent lifelines at all times to a fall hazard must be protected by a guardrail system, safety net system, or personal fall arrest system. Scaffolding applications also differ depending on the work being done. Because the use of scaffolding is rare within the county, If wire rope is used for top rails, it be flagged at not more shall. Railings stainless steel cable is another great way to ensure your views aren't blockedby your own guardrail. These railing materials are the epitome of security, and, in order to comply with OSHA standards, guardrails must be a height of 42 inches, plus or minus three inches, which is easily done with railings stainless steel cables

29 CFR § 1926.1431 - Hoisting personnel. CFR US Law ..

Crane Safety - Princeton Universit

Subpart M: Fall Protection, OSHA 1926 Construction UpCode

guardrails. (See Chapter 18: Guardrails in this manual for more information.) Note that before guardrails are in place, or if they have to be removed temporarily, workers must be protected by another means of fall protection (Figure 19-1). If it is not practicable to install guardrails, the next best option is to use travel restraint Guardrails • Top of the rail must be 42 ± 3 above the work surface and withstand 200lbs. outward or • Be made of rope wire or chain between 34 and 39 above surface height Please fill in the blanks if this system is to be used: • Must have anchorage capable of supporting 5000 lb loa

d. the rope, wire or chain must have a minimum tensile strength of 2.2 kN (500 lbs). An equally effective method might be a substantial barrier e.g. pile of materials or supplies, tall parapet, building system pipes and ducts, etc. that is positioned between the worker and the unguarded edge, preventing the worker from getting to the edge Proper training is the first step to keeping workers safe around leading edges. Workers should be trained to recognize leading edges, the fall hazards they pose, and any risk of collapse associated with them. They should also be taught how to use fall protection equipment, erect barriers and guardrails, and know what kind of signage is required They are also used to identify roof areas where work may be conducted without guardrails, harnesses, or safety nets (see Designated Areas below). OSHA warning lines may be made of rope, wire, or chain, and they must have a minimum tensile strength of 500 pounds

OSHA Fall Protection Requirements in General Industr

20 Posts. #16 · Nov 14, 2012. OSHA will permit a safety monitor to be used when workers ARE outside the lines to monitor the employees working outside the lines. The safety monitor, however, cannot be outside the lines while monitoring. Lines must be set up at minimum 6 feet from edge (A) Wire type: A fixed length of wire rope with mechanical fittings at both ends for pinning segments of wire rope together. (B) Bar type: Instead of wire rope, a bar is used. Pendants are typically used in a latticed boom crane system to easily change the length of the boom suspension system without completely changing the rope on the drum. (4.1) If part or all of the top rail or a midrail of a guardrail that is temporarily installed during the construction, demolition, maintenance or renovation of a work area is made of fibre rope, wire rope, chain or other non-rigid material, that part of the guardrail must meet the requirements of WorkSafeBC Standard — Guardrails using rope.

Inspections are critical and MUST be done before a platform can be used. Inspect building supporting structures every 12 months. Inspect all parts of the equipment according to the manufacturer's suggested time interval but not to exceed 12 months. This inspection includes wire ropes, bearings gears, and governors If wire rope is used for toprails, it must be flagged at not more 6 feet intervals (1.8 meters) with high-visibility material. And more Whatever the safety application need, an OSHA compliant solution can be found within the Kee Safety categories of roof fall protection products. Explore our collective fall protection products below Cranes and associated rigging equipment must be inspected regularly to identify any existing or potentially unsafe conditions. Regular inspections are before use and during use. If there are problems, get them fixed before continuing work. Preventive maintenance must also be done per crane manufacturer and/or the supplier specifications Wire rope at least 10 mm (3/8 in.) in diameterToe-board: At least 90 mm high and securely fastened to the inner side of the postsSection 3.8.4. - Metal guardrails: Metal guardrails shall be designed, constructed, installed and maintained in such a way as to offer a resistance and a safety equal or superior to that required for wooden guardrails Where hazards can be eliminated, to the employer must do so. It may be possible to elimi-nate or prevent the fall hazard by changing work procedures, redesigning the working envi-ronment, installing a guardrail, or using passive fall protection. When this is not possible, use of personal fall protection may be required

Horizontal Lifelines - An Introduction - Sesco Safet

In addition, cooking must be managed in a small space that moves with the motion of the vessel. Store utensils in racks and drawers, and use a guardrail on the stove to help stop pots and pans from moving. Make sure that cabins and living quarters are well ventilated, and use alarms to alert the crew (e.g., carbon monoxide detectors) 16.2.4 Inspection of Used Wire Rope. A used wire rope shall be thoroughly inspected prior to installation. 16.2.5 Inspection of Wire Rope on Idle Equipment. The wire rope on equipment that has been idle or shut down for a period of one month or more shall be completely inspected prior to operation. 16.2.6 Surfaces Contacted by Wire Rope If hand signals are utilized, both the operator and the signal person must provide documented proof of training of the Standard Method of hand signals as can be found in Appendix A of OSHA's crane standard. If radios or cell phones are used to communicate, they must be tested on-site prior to beginning operations An example of this type of scaffold is a chimney hoist, used in chimney-cleaning operations.Multi-point adjustable scaffolds must be suspended from metal outriggers,brackets,wire rope slings,hooks or means that meet equivalent criteria for strength, durability, etc.When two or more scaffolds are used they must not be bridged together unless.

Synthetic and natural rope used in suspension scaffolding must be protected from heat producing sources. worn or damaged wire rope is removed from service. Guardrails, hand holds and steps are provided for safe and easy access to and from all areas of the crane. It can also be a hazard to people in surrounding properties. Fire can be a. When a wire rope bridle is used, each leg must be connected to a master line (D-ring) or shackle with the load evenly distributed. Don't use the bridle for any other purpose. All rigging hard w a r e must be able to s u p p o r t five times the maximum in-tended load. If nonrotational rope is used, increase the safety factor to 10 • Wire or fiber rope used for scaffold suspension shall be capable of supporting at least 6 times the intended load. • Special precautions shall be taken to protect scaffold members, including any wire or fiber ropes, when using a heat-producing process. • The use of shore scaffolds or lean -to scaffolds is prohibited

How to Build Guardrails Like a Professional - Fall

• Rails must be of 2 x 4-inch lumber, flat bar, or pipe. o When used with rigid supports, taut wire or fiber rope of adequate strength may be used. o If the distance between supports is more than 8 feet, rails must be equivalent in strength to 2 x 4-inch lumber. o Rails must be firmly secured diameter. If wire rope is used for top rails, it needs to be flagged with a high-visibility material at least every 6 feet and can have no more than 3 of deflection The top rail needs to withstand a force of 200 pounds when applied in any downward or outward direction OSHA has taken verbiage directly from the original ANSI fall protection standard that was re ratified in Manufactured fall protection components used in the fall protection system must meet applicable sections of ANSI/ASSE Z359 Fall Protection Code. Assumptions are given which quantify elasticity of wire rope, synthetic ropes, and. * Hooks used on lifting equipment should be fitted with safety devices to prevent the load or sling displacement for the hook. * Do not use wire rope slings if it is kinked, crushed, frayed or corroded. * Slings must never be shortened by tying knots in them or by wrapping around a crane hook. Q. What are the Potential HAZARDS while performing. (f) Wire-rope slings - (1) Sling use. Employers must use only wire-rope slings that have permanently affixed and legible identification markings as prescribed by the manufacturer, and that indicate the recommended safe working load for the type(s) of hitch(es) used, the angle upon which it is based, and the number of legs if more than one

Personal Fall Arrest Systems • Snap hooks should not be engaged as follows: Directly to webbing, rope, wire rope To each other To D-ring that has another snap hook attached To a horizontal lifeline • Maximum free-fall distance not to exceed 6 feet. • Consideration should be given to total fall distance. PPT-012-02 15 16 The SafetyRail 2000 Guardrail is an OSHA Fall Protection guardrail. OSHA guardrails and roof railings ensure OSHA Compliance using a passive fall protection system. The SafetyRail 2000 Guardrail is part of BlueWater Manufacturing's SR2K system, a non-penetrating, passive fall protection system for workplace safety in rooftop or ground level.

Training must also include the installation of fall protection, particularly guardrails, and the proper selection, use and care of fall arrest equipment.The competent person(s) should receive additional training regarding the selection of scaffolds, recognition of site conditions, scaffold hazard recognition, protection of exposed personnel and. Frank Lill Son Inc v. Sec Labor, et al, No. 03-1096 (D.C. Cir. 2004) case opinion from the U.S. Court of Appeals for the District of Columbia Circui The competent person must inspect all machinery and equipment prior to each use, and during use, to make sure it is in safe operating condition. If it needs fixing, take it out of service and don't use it until it is fixed Broken Track APPLICABLE OSHA STANDARD 1926.550(a)(5) The employer shall designate a competent person who shall inspect al The Secretary of Labor (Labor), through the Occupational Safety and Health Administration (OSHA), cited Frank Lill & Son, Inc. (Lill) for willful violation of 29 C.F.R. § 1926.501(b) (1) which requires an employer to provide fall protection where employees work on a surface with an unprotected edge more than 6 feet above the level below The warning line system must be erected on all open sides of the work area and consist of stanchion posts with flagged wire, rope or chain. When mechanical equipment is not being used, the warning line must be erected at least 6 feet (1.83m) and no more than 25 feet from the roof edge